2R 支路上端接到 Vin(1)或 GND(0);节点电压随拨码变化,节点 R 链在下方。MSB 节点经运放电压跟随器缓冲输出(高阻输入、增益 1),Vout = +Vin·D/2N,输出阻抗恒为 R。2R 支路中的电流由梯形网络逐位二分、且与开关位置无关;开关只把恒定电流导向 GND(0)或运放反相输入端(1)。反相端为虚地(≈0V,与 GND 等电位),同相端接地,反馈 Rf = 2R,Vout = −Vin·D/2N。| 位数 N \ 目标档位 | −3 dB | −6 dB | −9 dB | −12 dB | −18 dB | −20 dB |
|---|---|---|---|---|---|---|
| 理论幅度 | 70.79% | 50.12% | 35.48% | 25.12% | 12.59% | 10.00% |
| 4 位 | 68.75% | 50.00% | 37.50% | 25.00% | 12.50% | 12.50% |
| 6 位 | 70.31% | 50.00% | 35.94% | 25.00% | 12.50% | 9.38% |
| 8 位 | 70.70% | 50.00% | 35.55% | 25.00% | 12.50% | 10.16% |
| 10 位 | 70.80% | 50.10% | 35.45% | 25.10% | 12.60% | 9.96% |
| 12 位 | 70.80% | 50.12% | 35.47% | 25.12% | 12.60% | 10.01% |